User manual H3003D

Technical parameters:

 

1. Working voltage DC12V

2. Working current <100 mA

3. Heavy volume 80g

4. Read card types: EM/ID 125Khz

5. Ambient temperature -20 to 60 degrees

6. Card reading distance: 1-10cm

Set the map:

Step 1: Power off, connect S1 jumper cap 2, 3, side, return to electricity, three nights after green flash.

Step 2: Brush two consecutive blank cards (the first to increase the card, the second to remove the card), the red light flashes, short continuous at this time.

Step 3: Power off, reconnect jumper cap 1, 2, and finally to electricity, increase the board.

Add or remove users:

Add user: In sleep mode, brush "add card", then brush to add user card in a row, then brush "add card" to exit

Delete users: In sleep mode, brush "Del card", then brush to delete user card in a row, then brush "Del card" to exit

Delete all users: in sleep mode, brush "Del card", then brush "add card", then brush "Del card" to exit.