Product Description


Product Name: W88 Digital Temperature Controller

Temperature measuring range: -50 ~ 110°C

Temperature control range: -19 ~ 99°C

Temperature measurement accuracy: ±0.3°C

Resolution: 0.1°C

Temperature probe: NTC10K/B3435

Power Voltage: DC 12V/AC 220V (optional)

Output current: 10A

Overall size: 81x55x31mm/3.19x2.17x1.22"

Please allow 1-3mm error due to manual measurement. Please make sure you do not mind before bidding

Due to the difference between different monitors, the picture may not reflect the actual color of the item. THANKS!


Noticed:


12V/220V wiring method is actually the same, 12V wiring should distinguish between Positive and negative, 220V wiring should distinguish between live wire (L) and neutral wire (N)

Instructions


SET function switch/switching machine

In the power-on state, press and hold the SET button for 3 seconds to turn the machine on and off.

In the off state, press the SET button to turn on

In normal use, press the SET button to perform F-1 (intermittent work), F-2 (timed stop), F-3 (timed start), function switching (F1-F3 are additional functions used, and the temperature control setting does not matter, so do not use it)

F-1 Intermittent work Setting the start minutes on the left Setting the stopping minutes on the right

F-2 timed shutdown, left hour, right minute, maximum can be set to 99 hours and 59 minutes

F-3 timed power on, left hour, right minute, the maximum can be set to 99 hours and 59 minutes

 

Temperature calibration

Eight times the thermostat socket, press and hold the SET button to turn on, enter the temperature correction function, the screen displays - -000- -, you can add or subtract the temperature according to the temperature before correction . Maximum range -9.9°C, after calibration, real-time temperature = temperature value before calibration + calibration value

Self-check function

Press and hold the left start temperature adjustment button at the same time, do not allow up and down, then turn on, you can enter the self-test function

Factory reset

Press and hold the right shift stop temperature adjustment button at the same time and do not send it up and down, then turn on the device, the screen displays 888, the buzzer beeps for a long time and factory reset is complete.

Write a review

Note: HTML is not translated!
Bad Good
12V Temperature Controller XH-W1411 W88
3,000.00DA
  • Stock: 1
  • Model: XH-W1411