Menu
Your Cart

Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output

Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output

 

Produit originale made in japan
Package included:
1x PID Digital Temperature Controller 
1x1m thermocouple K

 

Measuring accuracy: ±0.5%FS
Cold-end compensation tolerance: ±2C can be modified by software in 0~50C
Resolution: 14 bit
Sampling cycle: 0.5 Sec

 

Dimensions:48 x 48 x 110 (mm) ±0.2mm
Process value (PV), Setting value (SV) 
Output, alarm and self-tuning can be indicated by: LED

 

PIN control (including ON/OFF, step-type PID and continuous PID)
Self-tuning control
Relay output: contact capacity 250V AC 3A (resistive load) 
Alarm function output: 1 way
Contact capacity of output: 250V AC 3A (resistive load)
Setting value (SV): identical to measuring range (PV)
Proportional band (P): 0~full range (ON/OFF control when set to 0)
Integral time (I): 0~3600 sec (No integral action when set to 0)
Derivative time (D): 0~3600 sec (No derivative action when set to 0)
Heat-reset proportional cycle: 1~100 sec

 

Detective temperature range   0 to 400C 

Insulation resistance: >50M ohm(500V DC)
Insulation resistance: 1500V AC/min
Power Consumption: 10 VA
Service environment: 0~50C,
environment with no corrosive gas 30~85% RH
8
12

  

Write a review

Note: HTML is not translated!
Bad Good
Dual Digital RKC PID Temperature Controller REX-C100 with K thermocouple, Relay Output / SSR output
5,500.00DA
  • Stock: 6
  • Model: REX C-100
  • SKU: 1